MedLine DuraLoad

MedLine DuraLoad

 

 

Conair MedLine® DuraLoad™ vacuum receivers are the industry standard for trouble-free conveying of plastic pellets and regrinds. With more than 60,000 receivers installed worldwide, the DuraLoad answers the needs of processors who cannot afford to worry about the reliability of their material transfer systems. Available in either a hopper loading configuration with a discharge valve or direct feed models with a glass hopper, every DuraLoad may be outfitted to answer the needs of your operation with ratio loading capability, heavy duty wear plates, a choice of control voltages and many other options are also available.

  • Built ISO standards
  • Direct feed or hopper loading
  • Thick wall steel construction
  • Built-in Sequencing valves
  • Modular components
  • Choice of control
  1. Downloads
  2. Videos
  3. Contact Us

Contact Us Form

Click here

email

info@conairgroup.com

Phone

+1 724 584 5500

Parts & Service

+1 800 458 1960 - United States

+1 814 437 6861 - International

parts@conairgroup.com

service@conairgroup.com

Features (click here to hide)

Easy loading controls (ELC-16).

Universal Terminal Box (UTB).

Integrated Vacuum Sequencing Valve.

Direct Feed.

Options (click here to hide)

Volume Fill Sensor.

Material Valves.

Ratio Valve.

Common Line Valve.

High-Performance Valves.

Wear Plates.

Magnets.

Filter Drawer.

Screen Protector.

High-Heat Package.

Stainless Steel Material Contact.

Remote Demand Sensor.

Positive Discharge Valve.

Hopper Venting.

Knife Gate.

Specifications (click here to hide)

DL Series Vacuum Receivers
Receiver model DL8 DL12 DL15 DL20 DL25
Receiver diameter inches {mm} 8 {203} 12 {305} 15 {381} 20 {508} 25 {635}
Receiver volume ft³ {liters} 0.14 {4} 0.5 {14.2} 1.0 {28.3} 1.8 {51} 3.0 {85}
Material/Vacuum line size range inches {mm} 1.5-2 {38-51} 1.5-2.5 {38-64} 1.5-2.5 {38-64} 2.25-3 {57-76} 2.5-4 {64-102}
Receiver maximum temperature rating °F {°C} 180 {82}
with high-heat option °F {°C} 350 {177}
Filter type 20 mesh stainless steel disc
Available voltages (outputs) 120 VAC, 24 VAC and 24 VDC
Compressed air requirements Intermittent duty: 1ft³/min. @ 80 psi {28.3 liters/min. @ 5.51 bars} NPT fitting: 3/8 inch
Hopper Loading Configuration
Receiver model DL8 DL12 DL15 DL20 DL25
A - Height above mounting plate inches {mm} 12.19 {310} 17.375 {441} 20.8 {528} 26.19 {665} 33.75 {857}
B - Depth below mounting plate inches {mm} 5.5 {140} 8.375 {213} 8.375 {213} 9.5{241} 9.5 {241}
with positive discharge inches {mm} NA 16.0 {406} 16.0 {406} 16.0 {406} 16.0 {406}
C - Height to center of material inlet inches {mm} 6.19 {157} 9.5{241} 12.34 {313} 15.9 {404} 21.25 {540}
D - Height to center of vacuum outlet inches {mm} 10 {254} 14.4 {366} 17.5 {445} 22.625 {575} 29.19 {741}
Installed weight lb {kg} 22 {10} 41 {19} 49 {22} 69 {31} 99 {45}
Shipping weight lb {kg} 35 {16} 50 {23} 70 {32} 130 {59} 225 {102}
Direct Feed Configruation (glass hopper)
Receiver model DL8 DL12 DL15
Viewing chamber model 4 lb 15 lb 25 lb 4 lb 15 lb 25 lb 4 lb 15 lb 25 lb
Viewing chamber capacity lb {kg} 4 {1.81} 15 {6.8} 25 {11.3} 4 {1.81} 15 {6.8} 25 {11.3} 4 {1.81} 15 {6.8} 25 {11.3}
with isolator valve lb {kg} 3 {1.36} 11 {4.98} 21 {9.52} 3 {1.36} 11 {4.98} 21 {9.52} 3{1.36} 11 {4.98} 21 {9.52}
A - Height above mounting plate inches {mm} 24.0 {609} 29.5 {749} 41.5 {1054} 29.25 {742} 35.0 {889} 47.0 {1193} 32.5 {825} 37.75 {958} 49.75 {1263}
B - Height to center of material inlet inches {mm} 17.75 {450} 23.25 {590} 35.25 {895} 21.25 {539} 27 {685} 39 {990} 23.75 {603} 30.5 {774} 42.5 {1079}
C - Height to center of vacuum outlet inches {mm} 22.75 {577} 27.25 {692} 39.25 {996} 26.5 {673} 32.25 {819} 44.25 {1123} 29.25 {742} 35.0 {880} 47.0 {1193}
Add for isolator valve inches {mm} 0 0 0 2.25 {57} 2.25 {57} 2.25 {57} 2.25 {57} 2.25 {57} 2.25 {57}
Installed weight lb {kg} 49 {22} 51 {23} 80 {36} 68 {31} 70 {32} 99 {45} 76 {34} 78 {35} 107 {49}
Shipping weight lb {kg} 77 {35} 79 {36} 108 {49} 96 {44} 98 {44} 127 {58} 104 {47} 106 {48} 135 {61}