MedLine TW-P

MedLine TW-P

 

 

The MedLine® Thermolator TW-P Series is designed as the top-of-the-line Thermolator package. The MedLine TW-P offers extensive options for maintaining the process temperature with circulated water that has been heated or cooled to the required setpoint.
All models offer incoloy heaters; silicon carbide pump seals; pressure gauges; easy-to-use microprocessor controls and tool-free access panels for fast removal. The MedLine TW-P offers options including: process line purge, a choice of temperature control points, auto re-start capability, a variety of communications options, cool down mode, remote start/stop, stainless steel exterior panels and a disconnect switch.

  • Calibrated to ISO standards
  • Energy savings
  • Higher-effiency pumps
  • Incoloy heaters
  • "Casters up" warranty
  1. Downloads
  2. Videos
  3. Contact Us

Contact Us Form

Click here

email

info@conairgroup.com

Phone

+1 724 584 5500

Parts & Service

+1 800 458 1960 - United States

+1 814 437 6861 - International

parts@conairgroup.com

service@conairgroup.com

Features (click here to hide)

Built-in Pressure gauges.

Corrosion Resistance Package.

Incoloy heaters.

Three-piece cast construction.

High efficiency pumps.

Built-in sediment trap.

Options (click here to hide)

Compressed air purge valve.

Stainless steel.

Alarm packages.

Closed circuit with two brazed plate heat exchanger sizes.

Modulating cooling valve.

Stacking rack.

Communications options.

300° F construction.

SSR heater controls.

 

 

Specifications (click here to hide)

PERFORMANCE CHARACTERISTICS
Models TW-P (direct injection) TW-P (closed circuit)
Minimum setpoint temperature °F {°C} 40 {4} 40 {4}
Maximum setpoint temperature °F {°C} 250 {121} (300 {149} optional) 250 {121} (300 {149} optional)
Minimum operating temperature °F {°C} Approximately 20° {11°} above the cooling water inlet temperature
Standard cooling valve size inches {mm} 1/4 {6.35} 3/4 {19.05}
Available pump sizes 0.75, 1, 2, 3, 5, 7.5, or 10 Hp {0.56, 0.75, 1.49, 2.24, 3.73, 5.59, or 7.46 kW}
Connections to/from process NPT (female) 1.50 inches
Connections in/out cooling water NPT (female) 1.00 inches
Available heater sizes 6,9, 12, 18, 24, 36 or 48 kW 9, 12, 18 or 24 kW
PUMP PERFORMANCE - Consult your Conair representative for pump performance characteristics at other operating points.
Pump 3/4 Hp {0.56 kW} 1 Hp {0.75 kW} 2 Hp {1.49 kW} 3 Hp {2.24 kW} 5 Hp {3.73 kW} 7.5 Hp {5.59 kW} 10 Hp {7.46 kW}
Nominal flow gpm {lpm} 50 {189} 55 {208} 75 {284} 85 {322} 100 {379} 120 {454} 150 {568}
Pressure@ nominal flow psi {kg/cm²} 20 {1.4} 25 {1.7} 30 {2.1} 32 {2.2} 46 {3.2} 56 {3.9} 65 {4.5}
DIMENSIONS inches {mm}
Standard Cabinet, not including any connections  
A - Height 28.43 {722}
B - Width 14.00 {356}
C - Depth 25.75 {654}
SHIPPING WEIGHT RANGES lb {kg} Weights vary depending on cabinet size and cooling type (DI or CC).
  Single Zone
Pump Min Max
0.75 Hp {0.56 kW} 240 {109} 280 {127}
1 Hp {0.75 kW} 245 {111} 290 {132}
2 Hp {1.49 kW} 248 {113} 298 {135}
3 Hp {2.24 kW} 259 {118} 299 {136}
5 Hp {3.73 kW} 302 {137} 352 {160}
7.5 Hp {5.59 kW} 317 {144} 362 {164}
10 Hp {7.46 kW} 329 {149} 379 {172}
TOTAL FULL LOAD AMPS PER ZONE
Heater 9kW 12 kW
Voltage  208/3/60 230/3/60 380/3/60 400/3/50 460/3/60 575/3/60 208/3/60 230/3/60 380/3/60 400/3/50 460/3/60 575/3/60
Pump  Hp {kW}
0.75 {0.56} 25.9 25.9 15.0 15.0 12.9 10.5 33.4 33.4 19.3 19.3 16.7 13.5
1.0 {0.75} 26.8 26.8 15.2 15.3 13.3 10.6 34.3 34.3 19.5 19.6 17.1 13.6
2.0 {1.49} 28.9 28.9 16.6 16.7 14.3 11.6 36.4 36.4 20.9 21.0 18.1 14.6
3.0 {2.24} 31.7 31.7 13.4 18.0 15.4 12.5 39.2 39.2 22.4 22.3 19.2 15.5
5.0 {3.73} 36.3 36.3 20.7 18.2 17.7 14.2 43.8 43.8 25.0 22.5 21.5 17.2
7.5
{5.59}
42.1 42.1 24.9 20.5 20.3 16.3 49.6 49.6 29.2 24.8 24.1 19.3
10.0 {7.46} 50.3 50.3 28.9 24.8 24.1 18.9 57.8 57.8 33.2 29.1 27.9 21.9
TOTAL FULL LOAD AMPS PER ZONE
Heater 18 kW 24 kW
Voltage  208/3/60 230/3/60 380/3/60 400/3/50 460/3/60 575/3/60 208/3/60 230/3/60 380/3/60 400/3/50 460/3/60 575/3/60
Pump  Hp {kW}
0.75 {0.56} 48.5 48.5 28.0 28.0 24.2 19.5 63.6 63.6 36.6 36.6 31.7 25.6
1.0 {0.75} 49.4 49.4 28.2 28.3 24.5 19.6 64.5 64.5 36.8 36.9 32.1 25.7
2.0 {1.49} 51.5 51.5 29.6 29.7 25.6 20.6 66.6 66.6 38.2 38.3 33.1 26.7
3.0 {2.24} 54.3 54.3 31.1 31.0 26.7 21.5 69.4 69.4 39.7 39.6 34.2 27.6
5.0 {3.73} 58.9 58.9 33.7 31.2 29.0 23.2 74.0 74.0 42.3 39.8 36.5 29.3
7.5
{5.59}
64.7 64.7 37.9 33.5 31.6 25.3 79.8 79.8 46.5 42.1 39.1 31.4
10.0 {7.46} 72.9 72.9 41.9 37.8 35.4 27.9 88.0 88.0 50.5 46.4 42.9 34.0
TOTAL FULL LOAD AMPS PER ZONE
Heater 36 kW 48 kW
Voltage  208/3/60 230/3/60 380/3/60 400/3/50 460/3/60 575/3/60 208/3/60 230/3/60 380/3/60 400/3/50 460/3/60 575/3/60
Pump  Hp {kW}
0.75 {0.56} 93.7 93.7 54.0 54.0 46.8 37.6 N/A N/A N/A N/A 61.9 49.7
1.0 {0.75} 94.6 94.6 54.2 54.3 47.2 37.7 N/A N/A N/A N/A 62.3 49.8
2.0 {1.49} 96.7 96.7 55.6 55.7 48.2 38.7 N/A N/A N/A N/A 63.3 50.8
3.0 {2.24} 99.5 99.5 57.1 57.0 49.3 39.6 N/A N/A N/A N/A 64.4 51.7
5.0 {3.73} 104.1 104.1 59.7 57.2 51.6 41.3 N/A N/A N/A N/A 66.7 53.4
7.5
{5.59}
109.9 109.9 63.9 59.5 54.2 43.4 N/A N/A N/A N/A 69.3 55.5
10.0 {7.46} 118.1 118.1 67.9 63.8 58.0 46.0 N/A N/A N/A N/A 73.1 58.1