EnergySmart™ Dryer (ES-1)

EnergySmart™ Dryer (ES-1)
with TouchView Technology

The EnergySmart® Dryer with TouchView™ Technology combines traditional drying with an intuitive full-color, touch screen control that allows you to easily navigate and adjust all dryer system settings.  This new, powerful control is designed for variable throughputs of 400 to 5,000 lbs/hr {181 to 2,268 kg/hr}. 

All EnergySmart Dryers feature newly developed Optimizer™ Mode technology that automatically adjusts the dryer's blower to match your processing machine.  This ensures that you make high-quality, consistent product while dramatically reducing your energy costs.

Optional laoding, trending and recipe control screens further expand the capabilities of your EnergySmart Dryer System.

  • Easy-to-use, full-color touch screen
  • Real-time viewing of your process
  • Slash energy waste; reduce energy bill
  • Early warning-constant monitoring
  • Two year top-to-bottom warranty
  1. Downloads
  2. Videos
  3. Contact Us

Contact Us Form

Click here

email

info@conairgroup.com

Phone

+1 724 584 5500

Parts & Service

+1 800 458 1960 - United States

+1 814 437 6861 - International

parts@conairgroup.com

service@conairgroup.com

Features (click here to hide)

Variable frequency drive (VFD).

Optimizer™ mode.

Dew point monitor.

DM-II drying monitor.

Dew point control.

Options (click here to hide)

Trending screens.

Recipe screensLoading screens.

Communications.

Audible and visual alarm.

Allen-Bradley control.

Siemens control.

Specifications (click here to hide)
Model W600 W800 W1000 W1300 W1600 W2000 W2400 W3200 W4000 W5000
Performance characteristics (with full hopper)
Drying temperature All models 100° - 375°F {38°-191°C}
Dew point All models -40°F {-40°C}
Dimensions  inches {cm}
A - Height 93.6 {238.3} 92.2 {234.2} 98.3 {249.7}
B - Width 49.3 {125.2} 53.9 {136.9} 58.2 {147.8}
C - Depth 72.4 {183.9} 106.6 {270.7} 108.3 {275.0} 123.6 {313.9}
Outlet/inlet hose diameter 8.0 {20.3} 12.0 {30.5} 12.0 {30.5}
Weight  lbs {kg}        
Installed  1300 {590}  1300 {590}  1400 {636}  1600 {726}  2000 {907}
Shipping  1495 {678}  1495 {678}  1515 {687}  2620 {1188}  3385 {1535}
Voltage  Standard/Central full load amps        
400 V/3 phase/50 Hz 90.3/35.4 117.8/35.4  117.8/35.4  182.0/72.2 189.3/79.5  216.9/79.6 253.7/89.0 288.3/96.1 377.5/103.0  377.5/103.0
460 V/3 phase/60 Hz  80.2/32.4 104.8/32.4   104.8/32.4  160.5/64.9 167.8/72.2 192.2/72.7 224.3/80.9  255.6/88.3  334.3/95.4 334.3/95.4
575 V/3 phase/60 Hz  63.6/25.4  82.7/25.4 82.7/25.4 127.0/50.6 132.7/56.3 152.3/56.8 176.4/61.8 200.9/67.2 263.1/72.3 263.1/72.3
 Water requirements {for aftercooler/intercooler or optional precooler}       
 Recommended temperature 45° - 85°F {7° - 29°C}      
 Water flow  gal./min. {liters/min} 6-25 {22.7-94.6}    12-40 {45.4 -151.4}    15-50 {56.8-189.3} 
 Water connections  NPT 1  1/2 inch NPT