Thermolator TW-S Series

Thermolator TW-S Series

 

 

The new Thermolator TW-S Series takes everything that you loved about Conair's Reliable Thermolators of the past, and improves upon performance and available options. The TW-S offers a wide variety of options and features to make maintaining the process temperature at your required setpoint simple.

All models offer incoloy heaters; silicon carbide pump seals; pressure gagues; easy-to-use controls and tool-free access panels for fast removal. The TW-S options include: rotary non-fused disconnect switch, C-UL508A industrial control panel construction, hand-held remote control panel, solid state relay heater controls, brazed plate heat exchangers in two sizes, 300°F maximum operating temperature and vertical unit stacking rack.

  • State-of-the-art controls
  • Energy savings
  • Higher-efficiency pumps
  • Incoloy heaters
  • "Casters up" warranty
  1. Downloads
  2. Videos
  3. Contact Us

Contact Us Form

Click here

email

info@conairgroup.com

Phone

+1 724 584 5500

Parts & Service

+1 800 458 1960 - United States

+1 814 437 6861 - International

parts@conairgroup.com

service@conairgroup.com

Features (click here to hide)

Built-in pressure gauges.

Two-zone models.

Incoloy heaters.

High efficiency pumps.

Built-in sediment trap.

Options (click here to hide)

Modulating cooling valve.

Compressed air purge valve.

Corrosion resistance package.

Alarm packages.

Stacking rack.

Communications options.

SSR heater controls.

Closed circuit with two brazed plate heat exchanger sizes.

300° F construction.

Specifications (click here to hide)
PERFORMANCE CHARACTERISTICS
Models TW-S (direct injection) TW-S (closed circuit)
Minimum setpoint temperature °F {°C} 40 {4} 40 {4}
Maximum setpoint temperature °F {°C} 250 {121} (300 {149} optional) 250 {121} (300 {149} optional)
Minimum operating temperature °F {°C} Approximately 20° {11°} above the cooling water inlet temperature
Standard cooling valve size inches {mm} 1/4 {6.35} 3/4 {19.05}
Available pump sizes 0.75, 1, 2, 3, 5, 7.5, or 10 Hp {0.56, 0.75, 1.49, 2.24, 3.73, 5.59, or 7.46 kW}
Connections to/from process NPT (female) 1.50 inches
Connections in/out cooling water NPT (female) 1.00 inches
Available heater sizes 9, 12, 18, 24, 36 or 48 kW 9, 12, 18, 24 or 36 kW
PUMP PERFORMANCE - Consult your Conair representative for pump performance characteristics at other operating points.
Pump 3/4 Hp {0.56 kW} 1 Hp {0.75 kW} 2 Hp {1.49 kW} 3 Hp {2.24 kW} 5 Hp {3.73 kW} 7.5 Hp {5.59 kW} 10 Hp {7.46 kW}
Nominal flow gpm {lpm} 50 {189} 55 {208} 75 {284} 85 {322} 100 {379} 120 {454} 150 {568}
Pressure@ nominal flow psi {kg/cm²} 20 {1.4} 25 {1.7} 30 {2.1} 32 {2.2} 46 {3.2} 56 {3.9} 65 {4.5}
DIMENSIONS in. {mm}
Cabinet Style Single Zone (A) Dual Zone (B)
Height 28.43 {722} 28.43 {722}
Width 14.00 {356} 34.00 {864}
Depth 25.75 {654} 25.75 {654}
SHIPPING WEIGHT RANGES lb {kg} Weights vary depending on cabinet size and cooling type (DI or CC).
  Single Zone Dual Zone
Pump Min Max Min Max
0.75 Hp {0.56 kW} 240 {109} 280 {127} 491 {223} 576 {261}
1 Hp {0.75 kW} 245 {111} 290 {132} 499 {226} 584 {265}
2 Hp {1.49 kW} 248 {113} 298 {135} 515 {234} 590 {268}
3 Hp {2.24 kW} 259 {118} 299 {136} 538 {244} 623 {283}
5 Hp {3.73 kW} 302 {137} 352 {160} 629 {285} 699 {317}
7.5 Hp {5.59 kW} 317 {144} 362 {164} 649 {294} 729 {331}
10 Hp {7.46 kW} 329 {149} 379 {172} 683 {310} 763 {346}
TOTAL FULL LOAD AMPS PER ZONE
Heater 9kW 12 kW
Voltage  208/3/60 230/3/60 380/3/60 400/3/50 460/3/60 575/3/60 208/3/60 230/3/60 380/3/60 400/3/50 460/3/60 575/3/60
Pump  Hp {kW}
0.75 {0.56} 25.9 25.9 15.0 15.0 12.9 10.5 33.4 33.4 19.3 19.3 16.7 13.5
1.0 {0.75} 26.8 26.8 15.2 15.3 13.3 10.6 34.3 34.3 19.5 19.6 17.1 13.6
2.0 {1.49} 28.9 28.9 16.6 16.7 14.3 11.6 36.4 36.4 20.9 21.0 18.1 14.6
3.0 {2.24} 31.7 31.7 13.4 18.0 15.4 12.5 39.2 39.2 22.4 22.3 19.2 15.5
5.0 {3.73} 36.3 36.3 20.7 18.2 17.7 14.2 43.8 43.8 25.0 22.5 21.5 17.2
7.5
{5.59}
42.1 42.1 24.9 20.5 20.3 16.3 49.6 49.6 29.2 24.8 24.1 19.3
10.0 {7.46} 50.3 50.3 28.9 24.8 24.1 18.9 57.8 57.8 33.2 29.1 27.9 21.9
TOTAL FULL LOAD AMPS PER ZONE
Heater 18 kW 24 kW
Voltage  208/3/60 230/3/60 380/3/60 400/3/50 460/3/60 575/3/60 208/3/60 230/3/60 380/3/60 400/3/50 460/3/60 575/3/60
Pump  Hp {kW}
0.75 {0.56} 48.5 48.5 28.0 28.0 24.2 19.5 63.6 63.6 36.6 36.6 31.7 25.6
1.0 {0.75} 49.4 49.4 28.2 28.3 24.5 19.6 64.5 64.5 36.8 36.9 32.1 25.7
2.0 {1.49} 51.5 51.5 29.6 29.7 25.6 20.6 66.6 66.6 38.2 38.3 33.1 26.7
3.0 {2.24} 54.3 54.3 31.1 31.0 26.7 21.5 69.4 69.4 39.7 39.6 34.2 27.6
5.0 {3.73} 58.9 58.9 33.7 31.2 29.0 23.2 74.0 74.0 42.3 39.8 36.5 29.3
7.5
{5.59}
64.7 64.7 37.9 33.5 31.6 25.3 79.8 79.8 46.5 42.1 39.1 31.4
10.0 {7.46} 72.9 72.9 41.9 37.8 35.4 27.9 88.0 88.0 50.5 46.4 42.9 34.0
TOTAL FULL LOAD AMPS PER ZONE
Heater 36 kW 48 kW
Voltage  208/3/60 230/3/60 380/3/60 400/3/50 460/3/60 575/3/60 208/3/60 230/3/60 380/3/60 400/3/50 460/3/60 575/3/60
Pump  Hp {kW}
0.75 {0.56} 93.7 93.7 54.0 54.0 46.8 37.6 N/A N/A N/A N/A 61.9 49.7
1.0 {0.75} 94.6 94.6 54.2 54.3 47.2 37.7 N/A N/A N/A N/A 62.3 49.8
2.0 {1.49} 96.7 96.7 55.6 55.7 48.2 38.7 N/A N/A N/A N/A 63.3 50.8
3.0 {2.24} 99.5 99.5 57.1 57.0 49.3 39.6 N/A N/A N/A N/A 64.4 51.7
5.0 {3.73} 104.1 104.1 59.7 57.2 51.6 41.3 N/A N/A N/A N/A 66.7 53.4
7.5
{5.59}
109.9 109.9 63.9 59.5 54.2 43.4 N/A N/A N/A N/A 69.3 55.5
10.0 {7.46} 118.1 118.1 67.9 63.8 58.0 46.0 N/A N/A N/A N/A 73.1 58.1