Thermolator® vacuTrac

Thermolator® vacuTrac
Temperature Control Units

Keep your operation up and running with the Thermolator® vacuTrac water temperature controller. This positive/negative pressure unit can be used as a temporary fix for a leaky mold or bad O-rings.

 

The vacuTrac is equipped with a manual three-way ball valve that allows you to change the unit from positive pressure to negative pressure by moving the valve handle on the back of the unit counterclockwise. Changing the unit to operate with negative pressure allows the unit to draw air into the mold effectively stopping leaks.

  • Incoloy heaters
  • Three-way ball valve
  • Lift-off access panels
  • State-of-the-art controls
  • Compact, sturdy design
  1. Downloads
  2. Videos
  3. Contact Us

Contact Us Form

Click here

email

info@conairgroup.com

Phone

+1 724 584 5500

Parts & Service

+1 800 458 1960 - United States

+1 814 437 6861 - International

parts@conairgroup.com

service@conairgroup.com

Features (click here to hide)

Expansion/fluid reservoir.

Level switches.

Air/water separation tank.

High efficiency pump.

Overflow connection.

Venting line.

Pressure relief valve.

To process pressure gauge.

Three-way ball valve.

From process pressure gauge.

Jet pump/venturi.

Cooling water outlet.

Cooling check valve.

Cooling water inlet.

Options (click here to hide)

(TW-1) Control.

(TW-2) Control.

Alarm packages.

RS485 communication.

Specifications (click here to hide)

ELECTRICAL REQUIREMENTS- full load amps* VTR1-Dl VTR2-Dl
Heater 9 kW 12 kW 9 kW 12 kW
Voltage 208V 230V 460v 575v 208v 230v 460v 575v 208v 230v 460v 575v 208v 230v 460v 575v
Pump Sizes                
2 Hp   {1.49 kW} 31.8 28.8 14.4 11.5 40.2 36.4 18.2 14.6 63.6 57.6 28.8 23.0 80.4 72.8 36.4 29.1
3 Hp   {2.24 kW} 34.7 31.4 15.7 12.6 43.1 39.0 19.5 15.6 69.3 62.8 31.4 25.1 86.1 78.0 39.0 31.2
5 Hp   {3.73 kW} 38.5 34.8 17.4 13.9 46.8 42.4 21.2 17.0 76.9 69.9 34.8 27.8 93.7 84.8 42.4 33.9
7.5 Hp {5.59 kW} 45.7 41.4 20.7 16.6 54.1 49.0 24.5 19.6 91.5 82.8 41.4 33.1 108.3 98.0 49.0 39.2

 

MODELS VTR1-DI VTR2-DI
Performance characteristics
Minimum setpoint 32°F {0°C} 32°F {0°C}
Maximum setpoint 180°F {82°C} 180°F {82°C}
Pump performance per zone
Pump Size Hp {kW} 2 {1.49} 3 {2.24} 5 {3.73} 7.5 {5.59} 2 {1.49} 3 {2.24} 5 {3.73} 7.5 {5.59}
Nominal flow gpm {l/min} 55 {208} 80 {303} 100 {379} 115 {435} 55 {208} 80 {303} 100 {379} 115 {435}
Pressure @ nominal flow psi {bar} 31 {2.2} 35 {2.5} 43 {3} 51 {3.6} 31 {2.2} 35 {2.5} 43 {3} 51 {3.6}
Dimensions inches {mm}
A - Height 43 {1090} 43 {1090}
B - Width 14 {355} 28 {710}
C - Depth 31.5 {800} 31.5 {800}
Weight lb {kg}
Operating 300 {136} 305 {138} 310 {141} 320 {145} 600 {272} 610 {277} 620 {281} 640 {290}
Shipping 470 {213} 475 {216} 480 {218} 490 {222} 770 {349} 780 {354} 790 {358} 810 {367}
Water connections NPT inches {Female}
To/From Process 1.25 1.25
Cooling Water Inlet/Outlet 0.75

0.75