Externally mounted ratio valves connect readily to Conair vacuum receivers and loaders equipped with ratio-capable controls.
The dual inlets alternately open and close in response to a timed control signal, providing a mix of virgin and regrind materials during each vacuum loading cycle.
At rest, the regrind side is open and the virgin inlet is closed, allowing the valve to isolate the receiver from the common material line of central systems.
Contact Us Form
Phone
+1 724 584 5500
Parts & Service
+1 800 458 1960 - United States
+1 814 437 6861 - International
|
|
| Models | RV-1 | RV-2 | RV-3 | RV-4 |
| Performance characteristics | ||||
| Line size diameter inches {mm} | 1.5 - 2 {38.1 - 50.8} | 2.25 - 2.5 {57.2 - 63.5} | 3 {76.2} | 4 {101.6} |
| Type of inlet/outlet connection | screw-in | screw-in | welded | welded |
| Body type aluminum | cast | cast | fabricated | fabricated |
| Dimensions inches {mm} | ||||
| A - Overall height | 9.5 {241} | 10.5 {267} | 13.0 {330} | 13.0 {330} |
| B - Width | 12.5 {318} | 12.5 {318} | 13.25 {337} | 13.25 {337} |
| C - Height to top of lid | 4.75 {121} | 7.0 {179} | 8.0 {203} | 8.0 {203} |
| Weight lb {kg} | ||||
| Installed | 10 {5} | 13 {6} | 17 {8} | 17 {8} |
| Shipping | 14 {6} | 17 {8} | 21 {10} | 21 {10} |
| Voltage Total amps | ||||
| 120V/1 phase/60 Hz | 0.25 | 0.25 | 0.25 | 0.25 |
| 24V/1 phase/50 or 60 Hz | 1.0 | 1.0 | 1.0 | 1.0 |
| Compressed air requirement | ||||
| Air consumption | 0.2 ft³/min. @ 80 psi {0.09 liters/sec @ 5.5 bars} | |||
| Hose requirement | 1/4 in. hose fitting | |||