MCB cooling tanks provide flood or optional spray cooling of profile, tubing and pipe extrustions up to 6 inches {152 mm}.
The internal plumbing for flood cooling has been designed to provide maximum turbulence. This breaks up the warmer water that tends to surround and insulate the product, allowing maximum cooling efficiency. The spray cooling approach enhances the heat transfer rate through evaporative cooling.
An adjustable rotary water level control is used to easily adjust process water level for flood or spray cooling.
Contact Us Form
Phone
+1 724 584 5500
Parts & Service
+1 800 458 1960 - United States
+1 814 437 6861 - International
| Front View | Side View |
![]() |
![]() |
| Model | MCB-1 | MCB-2 | |||
| Tank Length ft. | 7 | 12 | 16 | 21 | 30 |
| Performance characteristics | |||||
| Tube/profile capacity | 1 inch {25mm} | Up to 2 inches {50 mm} | |||
| Pumps | .5 Hp | 2 Hp or 5 Hp water | |||
| Number of compartments | 2 | 2 | 2 | 2 | 2 |
| Size - Cooling / Air wipe | 6 inch {152mm} / 1 inch {25mm} | 11ft./1ft. | 15ft./1ft. | 20ft./1ft. | 29ft./1ft. |
| Dimensions inches {mm} | |||||
| A-Overall height | 55 {1397} | 55 {1397} | 55 {1397} | 55 {1397} | 55 {1397} |
| B-Height to centerline | 42 {1067} | 42 {1067} | 42 {1067} | 42 {1067} | 42 {1067} |
| C-Overall length | 84 {2134} | 180 {4572} | 216 {5486} | 288 {7315} | 396 {10058} |
| D-Tank length ft. {m} | 7 {2.1} | 13.5 {4.1} | 17.5 {5.3} | 22.5 {6.9} | 31.5 {9.6} |
| E-Overall width | 30 {762} | 48.5 {1232} | 48.5 {1232} | 48.5 {1232} | 48.5 {1232} |
| Tank compartment width | 8 {203} | 12 {306} | 12 {306} | 12 {306} | 12 {306} |
| Tank compartment height | 8 {203} | 8 {203} | 8 {203} | 8 {203} | 8 {203} |
| Approximate weight lb {kg} | |||||
| Shipping | 700 {318} | 2200 {998} | 2800 {1270} | 3500 {1587} | 4500 {2041} |
| Voltage available | 240V/3 phase/50-60 Hz or 480V/3 phase/50-60 Hz | ||||
| Water requirement | City, tower or chiller water; main supply line 1 inch NPT fitting | ||||
| Model | MCB-4 | MCB-6 | ||||||
| Tank length | 12 | 16 | 21 | 30 | 12 | 16 | 21 | 30 |
| Performance characteristics | ||||||||
| Tube/profile capacity | Up to 4 inches {101mm} | Up to 6 inches {152mm} | ||||||
| Pumps | 2 Hp, 5Hp, or 7.5 Hp water | |||||||
| Number of compartments | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 |
| Size - Cooling /Air wipe | 11ft./1ft. | 15ft./1ft. | 20ft./1ft. | 29ft./1ft. | 11ft./1ft. | 15ft./1ft. | 20ft./1ft. | 29ft./1ft. |
| Dimensions inches {mm} | ||||||||
| A-overall height | 55 {1397} | 55 {1397} | 55 {1397} | 55 {1397} | 55 {1397} | 55 {1397} | 55 {1397} | 55 {1397} |
| B-Height to centerline | 42 {1067} | 42 {1067} | 42 {1067} | 42 {1067} | 42 {1067} | 42 {1067} | 42 {1067} | 42 {1067} |
| C-Overall length | 180 {4572} | 216 {5486} | 288 {7315} | 396 {10058} | 180 {4572} | 216 {5486} | 288 {7315} | 396 {10058} |
| D-Tank length ft. {m} | 13.5 {4.1} | 17.5 {5.3} | 22.5 {6.9} | 31.5 {9.6} | 13.5 {4.1} | 17.5 {5.3} | 22.5 {6.9} | 31.5 {9.6} |
| E-Overall width | 48.5 {1232} | 48.5 {1232} | 48.5 {1232} | 48.5 {1232} | 48.5 {1232} | 48.5 {1232} | 48.5 {1232} | 48.5 {1232} |
| Tank compartment width | 12 {306} | 12 {306} | 12 {306} | 12 {306} | 14 {356} | 14 {356} | 14 {356} | 14 {356} |
| Tank compartment height | 12 {306} | 12 {306} | 12 {306} | 12 {306} | 14 {356} | 14 {356} | 14 {356} | 14 {356} |
| Approximate weight lb {kg} | ||||||||
| Shipping | 2200 {998} | 2800 {1270} | 3500 {1587} | 4500 {2041} | 2200 {998} | 2800 {1270} | 3500 {1587} | 4500 {2041} |
| Voltages available | 240V/3 phase/50-60 Hz or 480V/3 phase/50-60 Hz | |||||||
| Water requirements | City, tower, or chiller water;main supply lin 1 inch NPT fitting | |||||||