Heat Boosters supply economical drying heat to individual drying hoppers for the most efficient material pre-conditioning system available. With a temperature range up to 350°F {178°C}, and a full complement of safety devices, Heat Boosters are exceptional for providing safe, precise temperatures for drying.
Contact Us Form
Phone
+1 724 584 5500
Parts & Service
+1 800 458 1960 - United States
+1 814 437 6861 - International
Each Hopper Temperature Controller is equipped with a heater box that connects directly to the drying hopper and a precision DC temperature controller.
Fast responding, energy efficient heaters.
Accurate, safe temperature control.
| HTC for Carousel Plus Dryers | |||
| Front View | Side View | Control Front | Control Side |
![]() |
![]() |
![]() |
![]() |
| Model HTC | HTC-30H | HTC-60H | HTC-90H | HTC-120H | HTC-180H | HTC-270H | |
| Carousel Plus dryer model | W600 | W800 | W1000 | W1600 | W2400 | W3200 | W5000 |
| Performance characteristics | |||||||
| Temperature range | 150° - 375°F {66° - 191°C} | ||||||
| Flow rate cfm | 300 | 400 | 500 | 800 | 1200 | 1600 | 2500 |
| Pressure drop @ flow rate inches WC {mm WC} | 3.0 {76.2} | 1.8 {45.7} | 2.3 {58.4} | 4.0 {101.6} | 3.8 {96.5} | 5.9 {149.9} | 6.4 {162.6} |
| Heater box dimensions inches {cm} | |||||||
| Inlet size (OD) | 8 | 8 | 12 | 12 | 12 | 12 | |
| Outlet size selection (OD) | 8 | 8 | 12 | 12 | 12 | 12 | |
| A - Height | 31.4 {79.8} | 27.5 {69.9} | 27.0 {68.6} | 31.0 {78.8} | 34.0 {86.4} | 36.4 {92.5} | |
| B - Width | 10.1 {25.7} | 13.6 {34.5} | 16.0 {40.6} | 16.0 {40.6} | 18.0 {45.7} | 24.2 {61.5} | |
| C - Depth | 10.7 {27.2} | 10.9 {27.7} | 10.9 {27.7} | 16.0 {40.6} | 17.0 {43.2} | 17.0 {43.2} | |
| D - Height of discharge nozzle above the heater box | 1.75 {4.4} | 1.5 {3.8} | 2.0 {5.1} | 1.0 {2.5} | 2.0 {5.1} | 1.0 {2.5} | |
| E - Height of inlet nozzle below the heater box | 10.6 {26.9} | 7.1 {18.0} | 8 {20.3} | 10 {25.4} | 13 {33.0} | 15.4 {39.1} | |
| Installed weight lb {kg} | 38 {17} | 37 {17} | 78 {35} | 93 {43} | 102 {46} | 131 {59} | |
| Control center dimensions inches {cm} | |||||||
| F - Height | 24.0 {61.0} | 24.0 {61.0} | 36.0 {91.4} | 48.0 {122.0} | 60.0 {152.4} | 60.0 {152.4} | |
| G - Width | 24.0 {61.0} | 24.0 {61.0} | 30.0 {76.2} | 36.0 {91.4} | 42.0 {106.7} | 42.0 {106.7} | |
| H - Depth | 10.0 {25.4} | 10.0 {25.4} | 10.0 {25.4} | 10.0 {25.4} | 12.0 {30.5} | 120 {30.5} | |
| I - Clearance for heat sink | 3.0 {7.6} | 3.0 {7.6} | 3.0 {7.6} | 3.0 {7.6} | 3.0 {7.6} | 3.0 {7.6} | |
| Installed weight lb {kg} | 150.0 {68.0} | 150.0 {68.0} | 180.0 {81.6} | 250.0 {113.0} | consult Conair | consult Conair | |
| Voltage full load amps | |||||||
| 400V/3 phase/50 Hz | 44 | 87 | 131 | 175 | 261 | 381 | |
| 460V/3 phase/60 Hz | 38 | 76 | 114 | 152 | 227 | 340 | |
| 575V/3 phase/60 Hz | 30 | 61 | 91 | 122 | 182 | 272 | |