Conair's Carousel Dryers are now available with full-color touch screen control. Dubbed the Carousel Plus - everything about this new dryer is improved to help you stay profitable in a dramatically more competitive world market. Select a dryer package featuring TouchView™ controls for an indepth view into your drying process. Individual screens show you how your process is running and ways to improve it.
Purchase this dryer and you will find that you have more control over drying dew point and temperature than ever before, in a package that is simpler, smaller, lighter, more energy effiecient, easier to use and maintain than any other dryer on the market today.
Current Manual
Related specification sheets
Hopper Temperature Controller (HTC)
GasTrac Process Air Heater (CGT)
Related Manuals
HTC Manual with DC controls (English)
HTC Manual with DC controls (French)
HTC Manual with DC controls (Spanish)
Contact Us Form
Phone
+1 724 584 5500
Parts & Service
+1 800 458 1960 - United States
+1 814 437 6861 - International
![]() |
![]() |
| Model | W600 | W800 | W1000 | W1600 | W2400 | W3200 | W5000 |
| Performance characteristics (with hopper full) | |||||||
| Drying temperature | All models 100° - 375°F {38° - 191°C} with options | ||||||
| Dew point | All models -40°F {-40°C} | ||||||
| Dimensions inches {cm} | |||||||
| A - Height | 92.6 {235.2} | 95.4 {242.3} | 102.8 {261.1} | ||||
| B - Width | 43.3 {109.9} | 48.3 {122.7} | 48.9 {124.2} | ||||
| C - Depth | 57.4 {145.8} | 85.8 {217.9} | 112.0 {284.5} | ||||
| Outlet/inlet hose diameter | 8.0 {20.3} | 12.0 {30.5} | 12.0 {30.5} | ||||
| Approximate weight lbs {kg} | |||||||
| Installed | 1300 {590} | 1300 {590} | 1400 {636} | 1600 {726} | 1600 {726} | 2000 {907} | 2000 {907} |
| Shipping | 1495 {678} | 1515 {687} | 1515 {687} | 2100 {953} | 2620 {1188} | 3385 {1535} | 3385 {1535} |
| Voltage - Full load amps | |||||||
| 400 V/3 phase/50 Hz | 37.2 | 37.2 | 37.5 | 64.7 | 73.7 | 122.3 | 128.0 |
| 460 V/3 phase/60 Hz | 32.0 | 32.0 | 32.2 | 56.3 | 63.1 | 106.6 | 111.0 |
| 575 V/3 phase/60 Hz | 25.6 | 25.6 | 25.7 | 45.0 | 50.5 | 85.3 | 89.1 |
| Total kilowatts kW {BTU/min.} | 16.5 {939} | 17.5 {996} | 18.5 {1053} | 19.0 {1081} | 22.0 {1252} | 25.0 {1423} | 28.5 {1622} |
| Water requirements {for aftercooler/intercooler or optional precooler} | |||||||
| Recommended temperature | 45° - 85°F {7° 29°C} | ||||||
| Water flow gal./min. {liters/min.} | 6-25 {22.7 - 94.6} | 12 - 40 {45.4 - 151.4} | 15 - 50 {56.8 - 189.3} | ||||
| Water connections NPT | 1 1/2 inch NPT | ||||||