The Thermolator®heaTrac oil temperature controllercirculates heat transfer oil,adding or removing heat as needed to maintain a precise process temperature.
Certain materials and processes require the use of oil as a heat transfer fluid for precise temperature control. Unlike water or glycol mixtures,oil can be safely operated at temperatures ranging from 70ºF to 500ºF {21.1ºC to 260ºC}.
Contact Us Form
Phone
+1 724 584 5500
Parts & Service
+1 800 458 1960 - United States
+1 814 437 6861 - International
![]() |
![]() |
|
|
| Full load amps HTR1- 500 | ||||||||||||
| Heater | 6 kW | 12 kW | 18 kW | |||||||||
| Voltage | 208V | 230V | 460V | 575V | 208V | 230V | 460V | 575V | 208V | 230V | 460V | 575V |
| Pump | ||||||||||||
| 1 Hp {0.75 Kw} | 21.2 | 19.2 | 9.6 | 7.7 | 37.8 | 34.2 | 17.1 | 21.4 | 54.4 | 49.2 | 24.6 | 19.7 |
| 1.5 Hp {1.2 kW} | 21.9 | 19.8 | 9.9 | 7.9 | 38.5 | 34.8 | 17.4 | 13.9 | 55.0 | 49.8 | 24.9 | 19.9 |
|
2 Hp {1.49 kW} |
23.6 | 21.4 | 10.7 | 8.6 | 40.2 | 36.4 | 18.2 | 14.6 | 56.8 | 51.4 | 25.7 | 20.6 |
| 3 Hp {2.24 kW} | 26.5 | 24.0 | 12 | 9.6 | 43.1 | 39.0 | 19.5 | 15.6 | 59.7 | 54.0 | 27.0 | 21.6 |
| MODELS | HTR1-500 | |||
| Performance characteristics | ||||
| Minimum setpoint °F {°C} | 70 {21} | |||
| Maximum setpoint °F {°C} | 500 {260} | |||
| Pump performance | ||||
| Pump Size Hp {kW} | 1{0.75} | 1.5{1.12} | 2{1.49} | 3{2.24} |
| Nominal flow gpm {l/min} | 35{132} | 40{151} | 45{170} | 55{208} |
| Pressure @ nominal flow psi {bar} | 15{1.0} | 18{1.3} | 23{1.6} | 28{1.9} |
| Dimensions inches {mm} | ||||
| A - Height | 43 {1090} | |||
| B - Width | 14 {355} | |||
| C - Depth | 31.5 {800} | |||
| Weight lb {kg} | ||||
| Operating | 300{136} | 305{138} | 310{141} | 320{145} |
| Shipping | 470{213} | 475{216} | 480{218} | 490{222} |
| Oil connections NPT inches {Female} | ||||
| To/From Process | 1.25 | |||
| Cooling Water Inlet/Outlet* | 0.75 | |||