Premium Thermolator, for Ultimate Control

The Thermolator® TW-P Series is designed as the top-of-the-line Thermolator package. The TW-P offers extensive options for maintaining the process temperature with circulated water that has been heated or cooled to the required setpoint.

All models offer incoloy heaters; silicon carbide pump seals; pressure gauges; easy-to-use controls and tool-free access panels for fast removal. The TW-P options include: rotary non-fused disconnect switch, C-UL508A industrial control panel construction, hand-held remote control panel, solid state relay heater controls, brazed plate heat exchangers in two sizes, 300°F {149°C} maximum operating temperature and vertical unit stacking rack.

State-of-the-art controls

Microprocessor controls offer uniform temperature control regardless of external loading. Status lights, process supply and setpoint values are displayed on the control simultaneously. Built-in features include: cool down sequence, pump running hours count, temperature deviation alarms & warnings, adjustable alarm delay times, toggle to process return temperature, alarm horn & silence switch, error diagnostics and independent start and stop buttons.

Energy savings

This new generation of Thermolators is much more efficient. Offering as much as 50% increase in the pump operating envelope, an application that may have previously required a 5 Hp {3.73 kW} pump may now only require a 2 Hp {1.49 kW} pump. PLUS, today’s pumps use less energy than their predecessors. Average yearly operating cost savings of the new Thermolators is $740 per unit. Conair Sales can help determine which Thermolator suits your needs.

Higher-efficiency pumps

More efficient pumps— 36% wire to water to be exact. 3/4 Hp {0.56 kW} to 10 Hp {7.46 kW} pumps are available and feature silicon carbide seals and sediment traps for extended seal life. Cast iron impellers are standard.

TW-P Thermolator gauges
Built-in pressure gauges

Built-in pressure gauges are standard for all Conair TW Series Thermolators

Thermolator incoloy heaters
Incoloy heaters

Minimize chemical and high temperature damage

Thermolator three-piece cast construction
Three-piece cast construction

Eliminates potential leak points

Thermolator sediment trap
Built-in sediment trap

Settles contaminants away from the pump seals

MedLine® compressed air purge valve
Compressed Air Purge Valve

Quickly evacuates fluid from the process circuit, allowing for faster, cleaner disconnection of the temperature controller from molds and hoses.

MedLine® modulating cooling valve
Modulating Cooling Valve

Fully modulating cooling valve provides consistent temperature control while eliminating water hammer issues.

MedLine® alarm packages
Alarm Packages

Call attention to alarm conditions with red alarm strobe light.

Stacking Rack

Save floor space by stacking TCUs two-high. The stacking rack can be used only with single-zone models.

Closed Circuit with Two Brazed Plate Heat Exchanger Sizes

Offers greater performance, greater capacity, and less pressure drop.

Communications Options

Autostart/Remote start, Remote alarm dry contact, Remote temperature sensor.

Screenshots

Alarms

Display in real time with a complete alarm history

KPI

Dashboards display the Key Performance Indicators (KPI’s) in real time

material=set\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\rrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrr
Machine View

Graphic view of machine with real time readouts of set point vs. actual, as well as condition indicators (green means go, yellow means caution, red means needs attention)

Measurements

Display in real time historical trend lines of key measurements